The first variable area (VA) meter with rotating float was invented by Karl Kueppers in Aachen in 1908. The device was patented in Germany that same year. Felix Meyer was among the first to recognize the significance of Kueppers’ work and implemented the process for offering the meter for sale. In 1909, the firm of "Deutsche Rotawerke GmbH" was created in Aachen (Germany). They improved this invention with new shapes of the float and of the glass tube. It didn’t take long for the new device to capture attention in Europe, the United Kingdom, and other areas.

VA flow meters (or purge meters)

Over time, different types of VA flow meters (also called purge meters) have been developed, usually in response to some specific need. Nowadays a purge meter usually consists of a tapered tube, typically made of glass or plastic. Inside this tapered tube there is the ‘float’ which is made either from anodized aluminum or ceramic. The float is actually a shaped weight that is pushed up by the drag force of the flow and pulled down by gravity. The drag force for a given fluid and float cross section is a function of flow speed squared only.

While the meters are still relatively simplistic in design, relatively low cost, low maintenance and easy to install they are used in many kinds of application. Despite these facts, the traditional VA meter has a number of drawbacks. For instance, graduations on a given purge meter will only be accurate for a given substance at a given temperature and pressure. Either way, due to the direct flow indication, the resolution is relatively poor. Especially when they are built into a machine, reading might be hard. Moreover, the float must be read through the flowing medium, so you can imagine that some fluids may obscure the reading.

9 reasons why to use a thermal mass flow meter instead of a traditional purge meter

As for the current century, Bronkhorst has developed a thermal mass flow meter series (MASS-VIEW, as shown in picture 1) which is the digital high-tech alternative to the traditional VA flow meters. Thanks to today’s digital possibilities, many other advantages arise for many industrial processes and chemical plants.

bronkhorst-mass-view-flow-meter MASS-VIEW flow meter in application

  1. The MASS-VIEW flow meter series operate on the principle of direct thermal mass flow measurement (no by-pass); rather than measuring the volume flow it measures the actual mass flow, without the need of temperature and pressure correction.
  2. The digital OLED display provides an easy direct or relative reading of the actual flow. Herewith parallax errors are excluded.
  3. With this digital mass flow meter it is easily possible to obtain the accumulated flow. This availability of data gives insight in costs, leading to data driven decision making power.
  4. In contrast to the traditional VA meter which need to be mounted in a vertical position, this digital alternative can be mounted in any position.
  5. The flow path is made of sustainable aluminum rather than plastic or glass which is fragile.
  6. The instruments are standard equipped with 0-5V, RS-232 and Modbus-RTU output signals. Note that the traditional VA meters usually do not have any output signal available at all.
  7. As a standard feature, there are 2 built-in relays which indicate an alarm situation. Herewith, external devices can be controlled.
  8. Multi Gas; as opposed to traditional VA meters, which are produced for one particular fluid only, the digital alternative has up to 10 pre-installed gases available as a standard feature.
  9. Multi Range; traditional VA meters usually have a rangeability of 1:10 and one single full scale range only, the digital alternative has a rangeability of 1:100 as well as up to 4 pre-installed flow ranges.

Achieve a stable flow

A VA meter, whether it is a conventional or a digital one, can be equipped with a built-in needle valve. This needle valve enables the user to regulate the flow rate by means of a restriction inside the flow channel. As long as the inlet pressure is stable, the subsequent flow will be stable too. On the other hand, once pressure conditions are susceptible to change, the flow rate will become equally unstable. If this is not desirable, you’ll have to compensate these pressure fluctuations.

Flow control

Manual control valve

This effect can be eliminated by using a manual control valve like the FLOW-CONTROL series which keeps the pressure drop across the needle valve (delta-P) constant. This is accomplished by a second (normally open) valve, though it is operated by a membrane this time. The operating principle is based on a balance that forms between the pre-pressure, back-pressure and the spring force on the mebrane. A change in the pressure conditions leads to a change of the equilibrium and thus a change in the valve position as well (as shown in the picture below).

working-principle-control-valve Working principle of a pressure compensated control valve

Although Bronkhorsts’ pressure compensation technology is suitable for either gases and liquids, the nice thing about this is that both technologies, the digital VA meters and pressure compensation, lend themselves well to being built together. However, in that case it is applicable for gases only.

Learn more about the different models in the manual constant-flow control series

James Walton
Cover Image

This week I wanted to discuss pumps, dosing pumps in particular. Many of our customers want to combine flow meters with pumps and as a result we frequently get asked the same questions.

Why do we need to have a Coriolis mass flow meter if we use a dosing or metering pump?

Traditionally, and in most cases we see, dosing- or metering pumps are believed to be accurate because the theory is that a known pump head displacement will move a known volume over a known time giving a known delivered volume. In practice however it will never achieve a high level of accuracy with deviations of 10-15% being normal. Inaccuracies like this are caused by many changing process conditions, such as:

  • Temperature
  • Pressure shifting
  • Air entrapment
  • Wear of components

These factors can each be the cause of an inaccuracy in the expected volume of displacement from a pump head movement. If you then multiple each of those factors you can realise quite large measuring errors that create both inaccuracy and inconsistency. Please refer to our earlier blog about ‘High Accuracy’.

What can be done to improve the accuracy?

Option 1) Add a flow meter between the pump and the process

By adding a flow meter between the pump and the process, you can take information from the flow meter to adjust the speed of the pump. Traditionally, this would be managed with an analogue output signal, 4….20 mA or similar, from the flow meter into a separate PID controller that compares the real flow signal to the desired flow. Subsequently, the electronic controller can then adjust the speed of the pump to achieve the desired dose or flow.

Using this solution will mitigate the issues in the original solution, however it introduces more:

  • Slow flow signal due to signal filtering in the PID controller
  • Slow pump response due to extra control relay
  • Increased complexity with extra components
  • Time to achieve stable flow can be long
  • Additional price of meter and PID controller

Option 2) Direct mass flow measurement with a flow meter with built in PID control

Now we need to discuss the next possible solution, using a direct Mass Flow measurement device with built in PID control that can drive a pump to achieve the desired dose or flow.

With this solution you do not need to include the pump in the control system, just give a set point demand to the mass flow meter and it will drive the pump to achieve the desired dose or flow. This solution will give you several advantages, such as:

  • Direct mass flow control of the flow
  • Mass flow dosing is independent of temperature and pressure, in contrast to the volumetric dosing when only a pump is used;
  • Accurate delivery mitigating normal pump issues
  • Alarm functionality of low flow
  • Preventative maintenance based on pump performance over time
  • Consistent flow measurement based on actual not assumed numbers

Mini CORI-FLOW dosingbox

Coriolis mass flow meter in modular dosing system

These advantages can be utilised in many different industries:

Anywhere that liquid is dispensed into a container that will require quality assurance, and commonly the quality control test is carried out on a small percentage of the vials to ensure general compliance. If you use a mass flow meter to control the dose you can achieve 100% QC checking of your product with reduced human input.

If you need to dose additives, performance chemicals or mix liquids then the ability to control the flow of the additive and know what that flow is can be a huge advantage to the outcome of the application.

Washing Machine

Pump control can offer accurate dosing solutions for house hold chemicals like detergents and cleaning products.

Check out our blog about how pump control offers an unique way of accurate dosing solution for house hold chemicals like detergents and cleaning products.

• Also in the plastic industry you can use this solution. Check out the 5 reasons why additive dosing with a Coriolis instrument supports process efficiency.

• Check out our CORI-FILL Technology for ultra fast and precise batch dosing

Yann Le-Guenniou
Cover Image

In this blog, I would like to share an application of our flow instrumentation at one of our customers in which we needed to deal with high temperature and high pressure. This customer – an energy research organisation - investigates a catalysed chemical reaction of a mixture of hydrocarbon compounds.

Catalysts are being used to accelerate a chemical reaction without actually being consumed. So a small amount of catalyst is sufficient to obtain a large amount of reaction products.

Solid catalysts are often small, highly porous particles, with a large internal surface area in a small volume. This internal surface contains active sites on which the reaction takes place. Gaseous or liquid chemicals diffuse into the pores of these particles, and react at the catalytically active sites to reaction products that diffuse out of the particle. Often, these reactions occur at extreme process conditions.

What were the application requirements? A simple and reliable solution had to be found to inject a liquid flow at a high pressure. This injection has to take place at 30 to 60 bars, and needs to result in a stable flow without pulsation. Furthermore, the liquid flow needs to be controlled accurately, and during the process it has to be known how much liquid actually has been injected.

Which solution did the customer choose? The solution comprises a Coriolis mass flow meter that controls a HPLC piston pump at the inlet side of the reactor and an independently operating back pressure controller at the outlet side. The tested Coriolis mass flow meter (mini CORI-FLOW ML120) has proven to be a very stable and accurate mass flow meter. The WADose HPLC pump gives a very stable flow without pulsation. The combination of an HPLC pump and mass flow meter works as a mass flow controller. The control valve of the Coriolis mas flow meter is not necessary, as the pump is used as an actuator.

Image description

The pump can handle a liquid viscosity of max. 40 mPa.s at the upstream side. The maximum operating temperature is 70 °C. The temperature of the furnace that contains the reactor tube with small catalyst particles is much higher. The pressure at the reactor tube outlet has to remain at a high value. Beyond the outlet there is a cold trap for water or oil condensation, a back pressure controller with control valve that can handle pressure differences up to 400 bars and an exhaust to atmospheric pressure.

The pressure controller can handle gas and liquid in a very stable controlled flow. Especially at very small flow rates, this pressure controller has a much better control performance than a mechanical pressure reducer. The exhaust is used to remove gas that has been produced at the reaction.

The pump has three control modes: pressure, volumetric (only the speed of the piston is controlled) and mass flow. The latter is a special feature that can be offered, and is convenient from a chemist’s point of view. As the flow can be controlled directly, the exact number of moles injected to the process is known.

Image description

Control and monitoring occurs via the digital interface. The mass flow measure and setpoint, density, temperature and counter value are visible via this single digital interface.

The success of this setup has been demonstrated by a recent order of three additional pumps. For more details have a look at the application story 'Catalysis at high pressure'.

Want to learn more about flow management in catalyst research? Have a look at our Webinar ‘Flow Management in Catalyst Research’

Erik Tiemensma
Cover Image

Following the trend of big-data in today’s digitial world here at Bronkhorst, we see that it has also affected the world of flow measurement. The amount and speed of data transmission continues to increase and digital flow meters are employed in an even wider range of applications, such as at Universities and R&D institutes.

Thermal mass flow meters are a well-known instrument in this field. They measure the mass flow of gases, employing a combination of heated elements and temperature sensors, with thermodynamic principles used to derive actual flow. Mass flow meters need limited correction for changes in temperature, pressure or density and are extremely accurate, especially when measuring low and very low flow rates, and are no longer regarded as high cost.

Throughout the years, we’ve seen the technology improve, from a simple VA-meter to today’s ‘smart’ measuring device, like Bronkhorst’s EL-FLOW Prestige mass flow meter. Bronkhorst has used big-data to improve the technology within the mass flow meters and we still do, to keep the devices ‘intelligent’. The improved technology within the device makes it possible to select corresponding gas properties which are on-board, such as density and heat capacity, and to automatically adjust measurement values for environmental influences, for long-term sensor stability. Which, in turn, will directly relate to process yield.

There are many parameters, such as temperature and pressure, that have an influence on the accuracy, stability and reproducibility of a mass flow meter or controller. These are very important conditions within laboratory research.

Furthermore, to investigate the influence of as many gases as possible in a certain period of time, there is a need for short settling times as well as a quick change-over to a new gas with a very short downtime. Using a multi-gas/multi-range device can make a difference here, which offers the ability to use multiple gases at various process conditions with just one device.

Image description

Download white paper EL-FLOW Prestige mass flow controller For those of you interested in how we used big-data to optimize our thermal mass flow meter, the EL-FLOW Prestige, we have written a white paper containing in-depth information about influential factors and the impact on the accuracy, stability, linearity and pressure correction.

Please fill out the form and you’ll receive the whitepaper.



EL-FLOW Prestige Website

Rob ten Haaft
Cover Image

For many years, Mass Flow Controllers (MFCs) and Mass Flow Meters (MFMs) have been used in Analytical instrumentation. There are some distinctive applications like carrier gas control or mobile phase control in Gas Chromatography (GC) and Liquid Chromatography (LC). I discovered that there are a lot more applications of Mass Flow Controllers in analyzers then I could imagine when entering the world of Mass Flow Controllers after many years working in Analytical Chemistry.

One application I would like to focus on in this blog is Mass Spectrometry or shortly, as chemists like to use abbreviations, MS. Mass Spectrometry comes in many forms and is often coupled to Gas Chromatography and Liquid Chromatography. A Mass Spectrometer coupled to a Gas Chromatography (GC) is called a GC-MS and a Mass Spectrometer coupled to a Liquid Chromatography (LC) is called a LC-MS.

Where are Mass Spectrometers applied?

The market for Mass Spectrometers is huge and expanding. The instruments are used for Analytical Research in general but increasingly important in Food Research. Research concerning aging of whiskey and fingerprinting of red wine to determine the origin of the grapes are some examples. Another emerging market is Biopharmaceutical Research where Mass Spectrometers are used to study proteins and how these proteins are digested in living organisms. There are even Mass Spectrometers on Mars (!), where the martian soil is studied.

schematic mass spectrometer

Figure 1: Mass Spectrometer(schematic)

What is a Mass Spectrometer?

The Mass Spectrometer is often compared with a weighing scale for molecules. Every molecule is built up from atoms and every atom has its own atomic mass and this is “weighted” by a Mass Spectrometer. Before it can weigh the different atoms that are present in one sample, the atoms have to be separated from each other. This is done by charging the atoms (to form ions) and using a magnet to deflect the path that the ion is following. The lighter the ion, the more influence the magnet has and the bigger the deflection. The detector detects where the ion hits and this is a measurement of the weight.

The place where the ionization takes place is called the ion source and there are a lot of different types of ion sources, depending on the matrix of the sample and on the ions that you want to form. The ionizing part is the most interesting part from a Mass Flow point of view because in this part different gases are used, depending on the technique of ionization.

There are two main techniques: hard ionization and soft ionization. With hard ionization techniques, molecules in the sample are heated and fragmented down to atomic levels giving information about the atomic structure of the molecule. With soft ionization techniques the molecule stays more intact giving mass information of the molecule. This is used in Food and Pharma research and has become very popular in the last decade.

Let’s look into detail to one of the most popular soft ionization techniques, the Electrospray Ion Source. The EIS vaporizes the liquid (coming from a Liquid Chromatograph, for example) by leading gas alongside a charged needle to form an aerosol spray. Leading a counter gas flow through the formed spray will evaporate most of the liquid that you do not want to measure, leaving the charged droplets going into the Mass Spectrometer.

atmospheric pressure chemical ionization electrospray ionization electroscopy

Figure 2+3: Electrospray ionization (ESI)

Mass Flow Controllers and Evaporation used in Electrospray Ion source

The interesting part is that the flow needs to be very constant as you want the process of forming droplets and evaporating solvent to be the same, day after day and at different locations with different circumstances. An important parameter in this reproducibility is the gas flow. By using Mass Flow Controllers for Nebulizer gas and Evaporation or Drying gas, the ion source will always have reproducible gas flows.

Our solutions department can design compact gas modules for analytical applications to supply gases for ion-source combined with other gas flows with high accuracy and good reproducibility. Combining components like pressure switches and/or shut-off valves with the flow channels can give a compact gas handling module to fit in the small footprint demanding designs of the Mass Spectrometers. Furthermore, the changes on leaks are decreased significantly as the whole manifold can be leak and pressure tested before it is shipped to the customer.

If you would like to learn more about Bronkhorst customized flow solutions, you can watch this Video or visit our website.

Sandra Wassink
Cover Image

Did you know that natural gas is odorless? I didn’t… I always find it having a penetrating sulfur scent. Well, it appears that this penetrating scent is added to the natural gas on purpose. Let’s see why this is.

As natural gas is combustible and odorless by nature, the government requires some safety measures here. Many countries have established safety regulations how to handle natural gas and which gas needs odorisation. This is mostly done by the Health and Safety department (HSE) of the local government.

What about natural gas odorisation?

Today’s question is about this subject. Why does gas smell when it is odorless by nature? This is the point where gas odorisation comes in.

Odorisation of natural gas is done to act as a ‘warning agent’ in case of leakage. The idea is that people can smell the gas prematurely if it is present. Because, if there is too much gas present it can be explosive.

As shown in the picture, the LEL (Lower Explosive Limit) and UEL (Upper Explosive Limit) are crucial here. If the concentration of the combustible substance present in the air is too low (< LEL), than no combustion will occur. It the mixture is too rich (> UEL), there is a huge amount of gas in the air and only partial combustion will occur. Gases become dangerous in between the LEL and UEL. Therefore, it is most important for people in the surroundings to smell the gas in time, before the concentration is too high and it exceeds the LEL.

As a result, it is stated in the safety regulations that natural gas has to be detectable at a concentration level of 20% of the LEL and this is done by odorisation. Needless to say that the odor used in the gas is not dangerous to people’s health.

When is an odor added to gas?

This depends on the type of gas line. We know ‘distribution lines’ and ‘transmission lines’.
Distribution lines are local natural gas utility systems that include gas mains and service lines, such as the commercial gas used at domestic environments. All these distribution lines need to be odorised. For the transmission lines it is stated in the regulations when to odorise it.

Image description

Picture LEL and UEL

THT, Tetrahydrothiophene

For the odorisation there are many different odorants available, such as Tetrahydrothiophene (THT) and Mercaptan. Selecting the odorant depends on the properties of the gas to be odorised, pipeline layout, ambient conditions etc. Tetrahydrothiophene or THT is a well-known odor. THT is under ambient conditions a colourless volatile liquid with an unpleasant smell.

Controlled supply of THT using mass flow controllers

Bronkhorst had the pleasure of developing a solution for a Dutch customer to add THT to their biogas. Biogas was generated from anaerobic decomposition of organic matter and upgraded to natural gas quality to inject into the Dutch natural gas main. As commercial natural gas in the Netherlands has to contain at least 18mg of THT per cubic meter gas, the process of adding this to the commercial gas had to be done really accurately.

Image description

ATEX Zone 1 Coriolis Mass Flow Meter

The traditional approach to add THT is using a pump with a fixed stroke volume. However, low gas flow rates using a pump for batch-wise injection may lead to liquid THT remaining in the gas lines. THT may not be mixed well with the gas and might have the wrong concentration. A homogeneous injection of THT is therefore much better. Besides this, THT is a relatively expensive odor which also makes an accurate injection very much desired.

A better solution here would be using a combination of a pump with a Coriolis mass flow controller, in our case the mini CORI-FLOW™ series mass flow controllers. The Coriolis instruments make it possible to dose both continuously as well as accurately.

Read more about this application in our application note 'Controlled supply of odorant to natural gas'.

Hazardous areas

Something to be taken into account is the classification of the area. As gases in principle are explosive, it is very common for the environment around gases to be classified as a hazardous area. Most common classifications (in Europe) are marked as ATEX zone 1 or zone 2. Just make sure to select the right material to use.

For solutions such as THT odorisation processes, Bronkhorst can offer both ATEX/IECEx zone 1 and zone 2 solutions. Our mini CORI-FLOW Exd mass flow meter, for zone 1 applications, is a collaboration with one of world’s leading manufacturers in explosion protection, Electromach member of the R.STAHL Technology Group.

Check out our Coriolis mass flow meters for applications in hazardous areas and our thermal instruments for Atex zone 1.